Home | Contact Us | Sitemap | 中文 | CAS | Director's Email
 
Location:Home > Papers > Recent Papers
A novel purification method for high precision measurement of Ni isotopes by double spike MC-ICP-MS TEXT SIZE: A A A
Nickel (Ni) isotopes have been developed as a potential biosignature and proxy for tracing the occurrence of the Great Oxidation Event. However, the precise measurement of Ni isotopes is still hindered by the costly operation, complicated procedures and/or high procedural blanks of the chemical purification schemes. Here, a novel purification scheme, utilizing only dimethylglyoxime (DMG) and acetone as organic reagents, is proposed to separate Ni from samples through a four-step procedure with five chromatographic columns. Steps I, II and III are designed to effectively eliminate major matrix elements, including 99% Fe, Ca, Ti, and Al, 85% Mn, 55% K, even for samples with [Ca]/[Ni] approximate to 4600 and [Mg]/[Ni] approximate to 1900. Step IV utilizes the formation of Ni(DMG)(2) complexes in an aqueous medium containing 0.5 M HCl, 95% acetone and 0.1 M DMG, which can remove residual elements such as 45% K; this step avoids the use of Ni-specific resin, which requires careful pH tuning. Steps III and I can be repeated to obtain high-purity Ni. The Ni yield through these four steps is greater than 92%, with a maximum loss of similar to 8% occurring in Step II for low-Ni samples. The total procedural blank is 0.4 to 1.2 ng. When double spiking (Ni-61-Ni-60) is used to correct for instrument mass bias and purification-related isotope fractionation, small sample sizes (600-800 ng) are sufficient for achieving high-precision Ni isotope determination. Nickel isotopes for standards such as SRM 986 and geological reference materials (GRMs) such as BHVO-2, NOD-P-1, and NOD-A were determined on a Nu Plasma III MC-ICP-MS. The long-term reproducibility is 0.05 parts per thousand (2SD, n = 134) for pure solution and 0.06 parts per thousand (2SD, n = 18) for GRMs, and the average delta Ni-60 values are in excellent agreement with previous studies. These results show that our new purification method can be applied to various samples. Using this new method, we measured a set of granite, sediment, diamictite and loess samples and preliminarily constrained the delta Ni-60 of the upper continental crust to be 0.11 +/- 0.14 parts per thousand (2SD, n = 17).
 

Publication name

 JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 34 (8):1639-1651; 10.1039/c9ja00077a AUG 1 2019

Author(s)

 Wu, Guangliang; Zhu, Jian-Ming; Wang, Xiangli; Han, Guilin; Tan, Decan; Wang, Shui-Jiong

Corresponding author(s) 

 ZHU Jianming
 jmzhu@cugb.edu.cn  
 China Univ Geosci Beijing, State Key Lab Geol Proc & Mineral Resources, Beijing 100083, Peoples R China.

Author(s) from IGCAS   TAN Decan

View here for the details 

Copyright © Institute Of Geochemistry, Chinese Academy of Sciences All Rights Reserved.
Address: 99 West Lincheng Road, Guanshanhu District, Guiyang, Guizhou Province 550081, P.R.China
Tel: +86-851-85895239 Fax: +86-851-85895239 Email: web_en@mail.gyig.ac.cn